Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes

ABACUS/Manakin Repository

Show simple item record

dc.contributor.author Fernández-Vega, Luis spa
dc.contributor.author Madrid-Costa, David spa
dc.contributor.author Alfonso, José F. spa
dc.contributor.author Poo-López, Arancha spa
dc.contributor.author Montés-Micó, Robert spa
dc.date.accessioned 2013-11-27T17:26:19Z
dc.date.available 2013-11-27T17:26:19Z
dc.date.issued 2010 spa
dc.identifier.citation Fernández-Vega, L., Madrid-Costa, D., Alfonso, J. F., Poo-López, A., & Montés-Micó, R. (2010). Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes. European Journal of Ophthalmology, 20(1), 83-89. spa
dc.identifier.issn 11206721 spa
dc.identifier.uri http://hdl.handle.net/11268/637
dc.description.abstract PURPOSE. To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low-moderate myopia. METHODS. A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low-moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (CS) under photopic (85 cd/m(2)) and mesopic (5 cd/m2) conditions were determined. RESULTS. At the 6-month postoperative visit, there were no statistically significant differences in monocular and binocular BCVA (p=0.13 and p=0.22, respectively). Monocular and binocular BCNVA was comparable between the groups (p=0.26 and p=0.09, respectively). The mean binocular BCIVA changed significantly as a function of the distance of the test (p0.01). CONCLUSIONS. Bilateral implantation of the Acri.LISA 366D in high myopic eyes provides a satisfactory full range of vision comparable to that obtained in low-moderate myopic eyes. (Eur J Ophthalmol 2010; 20: 83-9) spa
dc.language.iso eng spa
dc.subject.other Multifocal Iol spa
dc.subject.other Myopia spa
dc.subject.other Visual Acuity spa
dc.subject.other Retinal-Detachment spa
dc.subject.other Contrast Sensitivity spa
dc.subject.other Visual Performance spa
dc.subject.other Distance spa
dc.subject.other Quality spa
dc.subject.other Extraction spa
dc.subject.other Risk spa
dc.subject.other Ophthalmology spa
dc.title Bilateral implantation of the Acri.LISA bifocal intraocular lens in myopic eyes spa
dc.type article spa
dc.description.impact 0.980 JCR (2010) Q3, 39/56 Ophthalmology spa
dc.rights.accessRights closedAccess en
dc.subject.unesco Oftalmología spa
dc.subject.unesco Vista spa
dc.subject.unesco Tratamiento médico spa
dc.peerreviewed Si spa