Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM

ABACUS/Manakin Repository

Show simple item record

dc.contributor.author Anitua, Eduardo
dc.contributor.author Flores, Carlos
dc.contributor.author Piñas Caballero, Laura
dc.contributor.author Alkhraisat, Mohammad Hamdan
dc.date.accessioned 2018-10-29T17:20:50Z
dc.date.available 2018-10-29T17:20:50Z
dc.date.issued 2018
dc.identifier.citation Anitua, E., Flores, C., Piñas Caballero, L., & Alkhraisat, M. H. (2018). Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM. Journal of Oral Implantology, 44(6), 427-431. https://doi.org/10.1563/aaid-joi-D-17-00229 spa
dc.identifier.issn 0160-6972
dc.identifier.issn 1548-1336
dc.identifier.uri http://hdl.handle.net/11268/7526
dc.description.abstract CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses. spa
dc.description.sponsorship Sin financiación spa
dc.language.iso eng spa
dc.title Frequency of technical complications in fixed implant prosthesis: the effect of prosthesis screw emergence correction by CAD-CAM spa
dc.type article spa
dc.description.impact 1.062 JCR (2018) Q4, 76/91 Dentistry, Oral Surgery & Medicine spa
dc.description.impact 0.573 SJR (2018) Q3, 25/50 Oral Surgery spa
dc.description.impact No data IDR 2018 spa
dc.identifier.doi 10.1563/aaid-joi-D-17-00229
dc.rights.accessRights closedAccess spa
dc.subject.uem Odontología restauradora spa
dc.subject.uem Prótesis dentales spa
dc.subject.uem Implantes dentales spa
dc.subject.unesco Odontología spa
dc.subject.unesco Tecnología médica spa
dc.description.filiation UEM spa
dc.peerreviewed Si spa


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record